modelIntDoor
Interior door
Extends from BondLib.Interfaces.TwoPort (Partial model invoking two bondgraphic connectors).
Information
The internal doors are similar to windows, in that they are thin and homogeneous. Thus the model contains an outside convection layer, no conduction layers, and (unfortunately) no inside convection layer either. This is the same error that the student made in modeling the windows.
Parameters
| Type | Name | Default | Description |
| Modelica.SIunits.ThermalConductivity | lv | 0.189 | Specific thermal conductivity of convection outside |
| Modelica.SIunits.Length | dxv | 1 | Width of convective layer outside |
| Modelica.SIunits.Area | area | | Area of door |
| Modelica.SIunits.ThermalResistance | thv | dxv/(lv*area) | Thermal resistance of convection outside |