Parameters: L: Reference inductance (default value = 1 H) Tnom: Reference temperature (default value = 300.15 oK) TL1: Linear temperature variation coefficient (default value = 0 1/oK) TL2: Quadratic temperature variation coefficient (default value = 0 1/oK2)
Equations:
DTemp = e2 - Tnom
Lval = L*(1 + TL1*DTemp + TL2*DTemp*DTemp)
p1 = Lval*f1
der(p1) = e1
f2 = 0