.BuildSysPro.BaseClasses.HeatTransfer.Components.WindConvection

Information

Hypothesis and equations

Model to calculate the convective heat exchange coefficient on the outside, depending on the wind speed and direction, for an horizontal or vertical wall.

Correlation comes from notice TF112 of CLIM2000, for these two specific cases :

An horizontal wall will be automatically considered as a leeward façade.

Bibliography

See notice TF112 from CLIM2000.

Instructions for use

none

Known limits / Use precautions

The model could be improved adding different correlations (roughness of the surface, tilt, wind direction...).

Validations

Validated model - Aurélie Kaemmerlen 2013

--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Aurélie KAEMMERLEN, EDF (2013)
--------------------------------------------------------------