Hypothesis and equations
Model to calculate the convective heat exchange coefficient on the outside, depending on the wind speed and direction, for an horizontal or vertical wall.
Correlation comes from notice TF112 of CLIM2000, for these two specific cases :
An horizontal wall will be automatically considered as a leeward façade.
Bibliography
See notice TF112 from CLIM2000.
Instructions for use
none
Known limits / Use precautions
The model could be improved adding different correlations (roughness of the surface, tilt, wind direction...).
Validations
Validated model - Aurélie Kaemmerlen 2013
--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Aurélie KAEMMERLEN, EDF (2013)
--------------------------------------------------------------
Name | Description |
---|---|
correlation |