.BuildSysPro.BaseClasses.HeatTransfer.Sources.FixedHeatFlow

Information

Hypothesis and equations

This model allows a specified amount of heat flow rate to be "injected" into a thermal system at a given port. The constant amount of heat flow rate Q_flow is given as a parameter. The heat flows into the component to which the component FixedHeatFlow is connected, if parameter Q_flow is positive.

If parameter alpha is > 0, the heat flow is mulitplied by (1 + alpha*(port.T - T_ref)) in order to simulate temperature dependent losses (which are given an reference temperature T_ref).

Bibliography

none

Instructions for use

none

Known limits / Use precautions

none

Validations

Validated model

--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Initial model : FixedHeatFlow, Anton Haumer, Copyright © Modelica Association, Michael Tiller and DLR.
--------------------------------------------------------------

Revisions

Mathias Bouquerel 12/2016 : remplacement du port thermique Modelica par le port thermique BuildSysPro