Record of Gauguin collective housing settings according to the date of construction
Hypothesis and equations
none
Bibliography
Site of the building stock library
Notes H-E10-1996-02908-FR and H-E13-2014-00591-FR
Instructions for use
none
Known limits / Use precautions
Warning : thermal bridges have been set to null because of a lack of data, it will be necessary to complete them when more details are available.
Validations
Validated model - Benoît Charrier, Philippe Petiot 06/2017
--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Benoît CHARRIER, Philippe PETIOT, EDF (2017)
--------------------------------------------------------------
record Gauguin2005 = BuildSysPro.BuildingStock.Utilities.Records.BuildingData.CollectiveHousing.BuildingDataGAUGUIN.BuildingType(UvitrageAF = 1.9, redeclare parameter WallData.CollectiveHousing.IntermediateFloor PlancherInterm, redeclare parameter WallData.CollectiveHousing.RT2005.Door Porte, redeclare parameter WallData.CollectiveHousing.IntDoor PorteInt, redeclare parameter WallData.CollectiveHousing.RT2005.ExtWall MurExt, redeclare parameter WallData.CollectiveHousing.PartitionWall Cloisons, redeclare parameter WallData.CollectiveHousing.SupportingWall Refends, redeclare parameter WallData.CollectiveHousing.RT2005.LandingWall MurPalier, redeclare parameter WallData.CollectiveHousing.RT2005.ExtWall MurCage, redeclare parameter WallData.CollectiveHousing.RT2005.Ceiling ParoiSousCombles, redeclare parameter WallData.CollectiveHousing.RT2005.Floor PlancherBas, redeclare parameter WallData.CollectiveHousing.CommonWall MurMitoyen, PontsTh_Generique = 0.00, PontsTh_Bas = 0.00, PontsTh_Haut = 0.00, TauxRenouvAir = 0.426, Hsext = 25, Hsint = 7.69, HsParoiSousCombles = 10);