Record of Matisse collective housing settings according to the date of construction
Hypothesis and equations
none
Bibliography
none
Instructions for use
Detail of thermal bridge vectors :
Known limits / Use precautions
Warning : thermal bridges have been set to null because of a lack of data, it will be necessary to complete them when more details are available.
Validations
Validated model - Benoît Charrier 12/2015
--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Benoît CHARRIER, EDF (2015)
--------------------------------------------------------------
record Matisse2012_MTD = BuildSysPro.BuildingStock.Utilities.Records.BuildingData.CollectiveHousing.BuildingDataMATISSE.BuildingType(UvitrageAF = 1.5, UvitrageSF = 1.5, redeclare replaceable parameter WallData.CollectiveHousing.IntermediateFloor PlafondMitoyen, redeclare replaceable parameter WallData.CollectiveHousing.RT2012_MTD.Door Porte, redeclare parameter WallData.CollectiveHousing.IntDoor PorteInt, redeclare replaceable parameter WallData.CollectiveHousing.IntermediateFloor PlancherMitoyen, redeclare replaceable parameter WallData.CollectiveHousing.RT2012_MTD.ExtWall MurExt, redeclare replaceable parameter WallData.CollectiveHousing.RT2012_MTD.LandingWall MurPalier, redeclare replaceable parameter WallData.CollectiveHousing.RT2012_MTD.Ceiling PlafondImmeuble, redeclare replaceable parameter WallData.CollectiveHousing.RT2012_MTD.Floor PlancherImmeuble, redeclare replaceable parameter WallData.CollectiveHousing.CommonWall MurMitoyen, redeclare replaceable parameter WallData.CollectiveHousing.PartitionWall Cloisons, bLNC = 0.1, bPlancher = 0.80, bPlafond = 1, ValeursK = {0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00}, TauPonts = {1, 1, 1, 1, 1, 1, 1, 1}, ValeursKPlafond = {0.00, 0.00, 0.00}, ValeursKPlancher = {0.00, 0.00, 0.00}, TauPontsPlafond = {1, 1, 1}, TauPontsPlancher = {1, 1, 1}, PontsTh_Generique = 0.00, PontsTh_Bas = 0.00, PontsTh_Haut = 0.00, renouvAir = 0.3, hsExtVert = 25, hsIntVert = 7.69, hsExtHor = 25, hsIntHorHaut = 10);
Benoît Charrier 05/2015 : ajout de paramètres nécessaires au modèle MatisseAssemblageLC
Benoît Charrier 06/2017 :
renouvAir
from 0,426 to 0,3 vol/h to fit with a humidity sensitive ventilation system which is commonly used in RT2012UvitrageAF
and UvitrageSF
from 1,2 to 1,5 W/m2.K which is more representative of RT2012