recordMozart2012_MTD

Settings of Mozart individual housing best available technology 2012

A record of BuildSysPro.BuildingStock.Utilities.Records.BuildingData.IndividualHousing.BuildingDataMOZART.BuildingType.

Information

Hypothesis and equations

none

Bibliography

none

Instructions for use

Detail of thermal bridge vectors :

  • TauPonts[1] and ValeursK[1] : exterior wall / exterior wall
  • TauPonts[2] and ValeursK[2] : exterior wall / supporting wall
  • TauPonts[3] and ValeursK[3] : exterior wall / floor
  • TauPonts[4] and ValeursK[4] : floor / crawlspace
  • TauPonts[5] and ValeursK[5] : supporting wall / floor
  • TauPonts[6] and ValeursK[6] : exterior wall / attic wall
  • TauPonts[7] and ValeursK[7] : attic wall / attic
  • TauPonts[8] and ValeursK[8] : door
  • TauPonts[9] and ValeursK[9] : windows

Known limits / Use precautions

Warning : thermal bridges have been set to null because of a lack of data, it will be necessary to complete them when more details are available.

Validations

Validated model - Benoît Charrier 12/2015

--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Benoît CHARRIER, EDF (2015)
--------------------------------------------------------------

Attributes

NameValue
UvitrageAF1.5
UvitrageSF1.5
renouvAir0.3
ValeursK{0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00}
TauPonts{1, 1, 1, 1, 1, 1, 1, 1, 1}
bLNC0.95
bPlancher1
bSousCombles1

Revisions

Benoît Charrier 06/2017 : editing value of air renewal renouvAir from 0,426 to 0,3 vol/h to fit with a humidity sensitive ventilation system which is commonly used in RT2012