Hypothesis and equations
none
Bibliography
none
Instructions for use
Detail of thermal bridge vectors :
Known limits / Use precautions
Warning : thermal bridges have been set to null because of a lack of data, it will be necessary to complete them when more details are available.
Validations
Validated model - Benoît Charrier 12/2015
--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Benoît CHARRIER, EDF (2015)
--------------------------------------------------------------
record Mozart2012_STD = BuildSysPro.BuildingStock.Utilities.Records.BuildingData.IndividualHousing.BuildingDataMOZART.BuildingType(redeclare replaceable parameter WallData.IndividualHousing.RT2012_STD.AtticWall ParoiSousCombles, redeclare replaceable parameter WallData.IndividualHousing.RT2012_STD.Door Porte, redeclare replaceable parameter WallData.IndividualHousing.RT2012_STD.Floor PlancherBas, redeclare replaceable parameter WallData.IndividualHousing.RT2012_STD.ExtWall Mur, redeclare replaceable parameter WallData.IndividualHousing.PartitionWall Cloisons, redeclare replaceable parameter WallData.IndividualHousing.SupportingWall Refends, redeclare replaceable parameter WallData.IndividualHousing.InteriorDoor PorteInt, UvitrageAF = 1.5, UvitrageSF = 1.5, renouvAir = 0.3, ValeursK = {0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00}, TauPonts = {1, 1, 1, 1, 1, 1, 1, 1, 1}, bLNC = 0.95, bPlancher = 1, bSousCombles = 1);
Benoît Charrier 06/2017 : editing value of air renewal renouvAir
from 0,426 to 0,3 vol/h to fit with a humidity sensitive ventilation system which is commonly used in RT2012