Hypothesis and equations
none
Bibliography
Site of the building stock library
Note H-E10-1996-02908-FR
Instructions for use
Detail of thermal bridge vectors :
Known limits / Use precautions
Warning : thermal bridges have been set to null because of a lack of data, it will be necessary to complete them when more details are available.
Validations
Validated model - Alexandre Hautefeuille, Gilles Plessis, Amy Lindsay 04/2014
--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Alexandre HAUTEFEUILLE, Gilles PLESSIS, Amy LINDSAY, EDF (2014)
--------------------------------------------------------------
record MozartBBCEffinergie = BuildSysPro.BuildingStock.Utilities.Records.BuildingData.IndividualHousing.BuildingDataMOZART.BuildingType(redeclare replaceable parameter WallData.IndividualHousing.BBCEffinergie.AtticWall ParoiSousCombles, redeclare replaceable parameter WallData.IndividualHousing.BBCEffinergie.Door Porte, redeclare replaceable parameter WallData.IndividualHousing.BBCEffinergie.Floor PlancherBas, redeclare replaceable parameter WallData.IndividualHousing.BBCEffinergie.ExtWall Mur, redeclare replaceable parameter WallData.IndividualHousing.PartitionWall Cloisons, redeclare replaceable parameter WallData.IndividualHousing.SupportingWall Refends, redeclare replaceable parameter WallData.IndividualHousing.InteriorDoor PorteInt, UvitrageAF = 1.5, UvitrageSF = 1.5, renouvAir = 0.426, ValeursK = {0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00, 0.00}, TauPonts = {1, 1, 1, 1, 1, 1, 1, 1, 1}, bLNC = 0.95, bPlancher = 1, bSousCombles = 1);