modelCO2TransportStep

Model with transport of CO2 through buoyancy driven flow

Extends from IBPSA.Airflow.Multizone.Validation.ThreeRoomsContam (Model with three rooms for the validation of the multizone air exchange models).

Information

This model is based on Buildings.Airflow.Multizone.Validation.ThreeRoomsContam. In addition, a CO2 source has been added to the left room in the bottom floor. At initial time, all volumes have zero CO2 concentration. At t=3600 seconds, CO2 is added to volWes. As time progresses, the CO2 is transported to the other rooms, and eventually its concentration decays.

Components

TypeNameDefaultDescription
IBPSA.Fluid.MixingVolumes.MixingVolumevolEas (from ThreeRoomsContam)Air volume east room
IBPSA.Airflow.Multizone.OrificeoriOutBot (from ThreeRoomsContam)Orifice at bottom of facade
IBPSA.Airflow.Multizone.MediumColumncolOutTop (from ThreeRoomsContam)Medium column for bottom floor outside air
IBPSA.Airflow.Multizone.OrificeoriOutTop (from ThreeRoomsContam)Orifice at top of facade
IBPSA.Airflow.Multizone.MediumColumncolEasInTop (from ThreeRoomsContam)Medium column for bottom floor
IBPSA.Fluid.Sources.Boundary_pTvolOut (from ThreeRoomsContam)Outside air boundary condition
IBPSA.Airflow.Multizone.MediumColumncolEasInBot (from ThreeRoomsContam)Medium column for bottom floor
IBPSA.Airflow.Multizone.MediumColumncolOutBot (from ThreeRoomsContam)Medium column for bottom floor outside air
IBPSA.Airflow.Multizone.MediumColumncolWesBot (from ThreeRoomsContam)Medium column for bottom floor
IBPSA.Airflow.Multizone.OrificeoriWesTop (from ThreeRoomsContam)Orifice between top and bottom west floor
IBPSA.Airflow.Multizone.MediumColumncolWesTop (from ThreeRoomsContam)Medium column for top floor
DoorOpendooOpeClo (from ThreeRoomsContam)
IBPSA.Fluid.MixingVolumes.MixingVolumevolWes (from ThreeRoomsContam)Air volume west floor
IBPSA.Airflow.Multizone.MediumColumncol1EasBot (from ThreeRoomsContam)Medium column for bottom floor
IBPSA.Airflow.Multizone.OrificeoriEasTop (from ThreeRoomsContam)Orifice between top and bottom east floor
IBPSA.Airflow.Multizone.MediumColumncolEasTop (from ThreeRoomsContam)Medium column for top floor
IBPSA.Fluid.MixingVolumes.MixingVolumevolTop (from ThreeRoomsContam)Air volume top floor
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureTTop (from ThreeRoomsContam)Fixed temperature
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureTWes (from ThreeRoomsContam)Fixed temperature
Modelica.Thermal.HeatTransfer.Sources.FixedTemperatureTEas (from ThreeRoomsContam)Fixed temperature
Modelica.Thermal.HeatTransfer.Components.ThermalConductorconTop (from ThreeRoomsContam)Thermal conductor
Modelica.Thermal.HeatTransfer.Components.ThermalConductorconWes (from ThreeRoomsContam)Thermal conductor
Modelica.Thermal.HeatTransfer.Components.ThermalConductorconEas (from ThreeRoomsContam)Thermal conductor
IBPSA.Fluid.Sensors.TraceSubstancesCO2SenTopCO2 sensor
IBPSA.Fluid.Sensors.TraceSubstancesCO2SenWesCO2 sensor
IBPSA.Fluid.Sensors.TraceSubstancesCO2SenEasCO2 sensor
Modelica.Blocks.Sources.PulsepulsePulse signal for CO2 flow source
IBPSA.Fluid.Sources.TraceSubstancesFlowSourcesouCO2 source

Revisions