.BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.Validation.InternalResistancesOneUTubeNegative

Validation of the thermal resistances using the method of Bauer et al. (2011) for a single U-tube borehole

Information

This example validates the implementation of IBPSA.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.internalResistancesOneUTube for the evaluation of the internal thermal resistances of a single U-tube borehole.

In this case, the shank spacing is defined such that the pipes are close to the borehole wall, rendering the short-circuit thermal resistances negative. The capacity location x is then automatically set to zero.

Revisions


Generated at 2025-03-10T19:24:30Z by OpenModelicaOpenModelica 1.24.5 using GenerateDoc.mos