.BuildSysPro.IBPSA.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.Validation.InternalResistancesTwoUTubeNegative

Information

This example validates the implementation of IBPSA.Fluid.Geothermal.Borefields.BaseClasses.Boreholes.BaseClasses.Functions.internalResistancesTwoUTube for the evaluation of the internal thermal resistances of a double U-tube borehole.

In this case, the shank spacing is defined such that the pipes are close to the borehole wall, rendering the short-circuit thermal resistances negative. The capacity location x is then automatically set to zero.

Revisions


Generated at 2024-11-22T19:25:38Z by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos