Power calculation comparison among three mover types, using exact power computation for m_flow and dp
This example is identical to
IBPSA.Fluid.Movers.Validation.PowerSimplified, except that the
performance data for the flow controlled pumps
pump_dp
and pump_m_flow
contain
the pressure curves and efficiency curves.
The plot below shows that this leads to a computation of the power consumption
that is identical to the one from the speed controlled pump pump_Nrpm
.
-
October 15, 2021, by Hongxiang Fu:
Fixed the image in the documentation which was cut off
at the y-axis. This is for
IBPSA, #1533.
-
March 2, 2016, by Filip Jorissen:
First implementation for
#417.