Function that calculates the specific isobaric heat capacity (cp) of R410A vapor based on temperature and specific volume.
The specific isobaric heat capacity is evaluated from the partial derivatives of the Martin-Hou equation of state.
F. de Monte. (2002). Calculation of thermodynamic properties of R407C and R410A by the Martin-Hou equation of state, part I: theoretical development. International Journal of Refrigeration. 25. 306-313.
Thermodynamic properties of DuPont Suva 410A: https://www.chemours.com/Refrigerants/en_US/assets/downloads/h64423_Suva410A_thermo_prop_si.pdf
function specificIsobaricHeatCapacityVap_Tv input Modelica.Units.SI.Temperature T "Temperature of refrigerant"; input Modelica.Units.SI.SpecificVolume v "Specific volume of refrigerant"; output Modelica.Units.SI.SpecificHeatCapacity cp "Specific isobaric heat capacity"; end specificIsobaricHeatCapacityVap_Tv;