modelWaterHeaterHeatPumpController

Simple Hysteresis control with Time of Use switch and Auto mode

Information

Hypothesis and equations

For detailed documentation, see WaterHeaterHeatPumpPoly model.

Bibliography

none

Instructions for use

none

Known limits / Use precautions

none

Validations

Validated model - Kévin Deutz 08/2017

--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Kévin DEUTZ, EDF (2017)
--------------------------------------------------------------

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.TemperatureT_set55 + 273.15HPWH setpoint temperature [K]
BooleanactivateTOUfalseActivate time of use prioritization
BooleanHP_onlyfalseHP only mode (no auxiliary back up)
BooleanmanualOnOfffalseActivate external manual on/off signal
Modelica.Units.SI.TemperatureT_set_low45 + 273.15HPWH setpoint temperature outside TOU period [K]
Modelica.Units.SI.TemperatureDifferencedelta_T10Temperature hysteresis [K]
Modelica.Units.SI.TemperatureT_min_HP273.15 - 5Minimal HPWH operating condition [K]
RealcompSpeed50Compressor operating speed [Hz]
RealcompIddleSpeed20.0

Connectors

TypeNameDefaultDescription
Modelica.Blocks.Interfaces.RealOutputfreqCompressor frequency [Hz]
Modelica.Blocks.Interfaces.BooleanOutputOnOffSystem on off signal
Modelica.Blocks.Interfaces.RealInputT_waterWater temperature [K]
Modelica.Blocks.Interfaces.RealInputT_airExternal air temperature [K]
Modelica.Blocks.Interfaces.BooleanOutputOnOffAuxiliaryAuxiliary on off control
Modelica.Blocks.Interfaces.BooleanInputonOffSwitchExternal on off switch

Components

TypeNameDefaultDescription
Modelica.Units.SI.TemperatureT_set_coldHP setpoint temperature at low external air temperatures [K]
BooleanminHPHP operating region for the heat pump
BooleanHystHysteresis signal
BooleanHystAuxHysteresis signal
BooleanTOUTime of use tarif signal
RealinitTime
Integerday