.BuildSysPro.Systems.DHW.Solar.SolarWaterHeater

Information

Hypothesis and equations

Called ISWH for individual solar hot water heater, this domestic hot water production system combines a solar sensor and a domestic hot water tank with an electric back-up.

It combines a solar sensor model and a domestic hot water model. Heat recovered by the plane sensor is transferred to the hot water tank.The hot water tank can be placed in a room heated or not. Refer to the sensor and the tank models for more information on their specificities.

Bibliography

none

Instructions for use

none

Known limits / Use precautions

This is a simplified model that does not take into account the heat transfer fluid, thus neither the sensor inertia nor the consumption of fluid circulation auxiliary are not taken into account.

Take care to respect the units of inputs such as the drawing scenario rate in kg / h.

Validations

Validated model - Hubert Blervaque 06/2011

--------------------------------------------------------------
Licensed by EDF under a 3-clause BSD-license
Copyright © EDF 2009 - 2023
BuildSysPro version 3.6.0
Author : Hubert BLERVAQUE, EDF (2011)
--------------------------------------------------------------

Revisions

Hubert Blervaque 06/2012 : Modification de la sortie réelle T_int en un port thermique correspondant à la zone dans laquelle est située le ballon ECS et à laquelle les pertes du ballon sont appliquées.

Benoît Charrier 01/2018 : Added T_out (output water temperature). Added choice between prescribed or fixed for the cold water temperature.


Generated at 2024-05-18T18:16:21Z by OpenModelicaOpenModelica 1.22.4 using GenerateDoc.mos