Model for a heat and moisture exchanger with constant effectiveness.
This model transfers heat and moisture in the amount of
QSen = epsS * Q_max, m = epsL * mWat_max,
where epsS and epsL are constant
effectiveness for the sensible and latent heat transfer,
Q_max is the maximum sensible heat that can be
transferred and mWat_max is the maximum moisture that
can be transferred.
For a sensible heat exchanger, use BuildingSystems.Fluid.HeatExchangers.ConstantEffectiveness instead of this model.
This model can only be used with medium models that define the
integer constant Water which needs to be equal to the
index of the water mass fraction in the species vector.
final prescribedHeatFlowRate1=true and final
prescribedHeatFlowRate2=true.Q1_flow did not include latent heat
flow rate.Medium1.Water by
introducing the parameter i1_w, and used a similar
construct for Medium2. This avoids an error during
model check as these constants are not known in the partial medium
model.mWat_flow in the
base class.