record WoodFibreInsulation = BuildingSystems.HAM.Data.MaterialProperties.BaseClasses.MaterialHygroThermalGeneral(id = 14, name = "Wood fibre insulation (Holzfaserdaemmplatte 1)", rho = 168, c = 1700, sorTabX = {0.0, 0.65, 0.8, 0.93, 1.0}, sorTabY = {0.0, 12.6, 17.3, 28.5, 526.0}, myTabX = {0.0, 1.0}, myTabY = {3.3, 3.3}, lambdaTabX = {0.0, 880.0}, lambdaTabY = {0.0381, 0.138}, dwwTabX = {0.0, 17.0, 526.0}, dwwTabY = {0.0, 2.0e-10, 3.0e-9}, dwsTabX = {0.0, 17.0, 526.0}, dwsTabY = {0.0, 1.9e-13, 1.5e-10}, lambdaDry = 0.0381, w80 = -999, w95 = -999, wF = 526.0, porosity = 0.88, A = 0.0033, myDry = 3.3, myMoistF = -999, moistSup = -999);