modelElectricalModelTwoDiodesMPP

MPP controlled electrical two diodes model of a PV module

Extends from BuildingSystems.Technologies.Photovoltaics.BaseClasses.ElectricalModels.ElectricalModelTwoDiodesGeneral (Basic electrical two diodes model of a PV module).

Information

This is a MPP controlled electrical two diodes model of a PV module.

Parameters

TypeNameDefaultDescription
IntegernCelPar (from ElectricalModelGeneral)Number of parallel connected cells within the PV module
IntegernCelSer (from ElectricalModelGeneral)Number of serial connected cells within the PV module
RealEg (from ElectricalModelGeneral)Band gap
Realc1 (from ElectricalModelTwoDiodesGeneral)1st coefficient IPho
Realc2 (from ElectricalModelTwoDiodesGeneral)2nd coefficient IPho
Realcs1 (from ElectricalModelTwoDiodesGeneral)1st coefficient ISat1
Realcs2 (from ElectricalModelTwoDiodesGeneral)2nd coefficient ISat2
RealRPar (from ElectricalModelTwoDiodesGeneral)Parallel resistance
RealRSer (from ElectricalModelTwoDiodesGeneral)Serial resistance

Connectors

TypeNameDefaultDescription
BuildingSystems.Interfaces.Temp_KInputT (from ElectricalModelGeneral)Cell temperature
BuildingSystems.Interfaces.RadiantEnergyFluenceRateInputITot (from ElectricalModelGeneral)Effective total solar irradiation on solar cell
BuildingSystems.Interfaces.PowerOutputP (from ElectricalModelGeneral)Module power
Modelica.Blocks.Interfaces.RealOutputI (from ElectricalModelGeneral)Module current
Modelica.Blocks.Interfaces.RealOutputUModule voltage

Components

TypeNameDefaultDescription
Modelica.Units.SI.VoltageUt (from ElectricalModelGeneral)Temperature voltage
Modelica.Units.SI.ElectricCurrentIPho (from ElectricalModelTwoDiodesGeneral)Photo current
Modelica.Units.SI.ElectricCurrentISat1 (from ElectricalModelTwoDiodesGeneral)Saturation current diode 1
Modelica.Units.SI.ElectricCurrentISat2 (from ElectricalModelTwoDiodesGeneral)Saturation current diode 2
ReallambdaLagrange multiplier

Revisions

  • March 1, 2015 by Christoph Nytsch-Geusen:
    First implementation.