.Buildings.Fluid.Movers.Validation.PowerExact

Information

This example is identical to Buildings.Fluid.Movers.Validation.PowerSimplified, except that the performance data for the flow controlled pumps pump_dp and pump_m_flow contain the pressure curves and efficiency curves. The plot below shows that this leads to a computation of the power consumption that is identical to the one from the speed controlled pump pump_y.

image

Revisions


Generated at 2024-11-26T19:26:15Z by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos