.Buildings.HeatTransfer.Windows.BaseClasses.Validation.HeatCapacityConstantShade

Information

This model validates the heat capacitor model for the window glass, with and without a shade. For the case with shade, different constant shade control signals are used to test the correct energy storage of the system. All temperatures need to decay at the same rates because the area of heat transfer, and the heat capacity to which the glass is connected, are scaled proportionally to the control signal.

Revisions


Generated at 2024-05-17T18:15:58Z by OpenModelicaOpenModelica 1.22.4 using GenerateDoc.mos