.Buildings.Media.Refrigerants.R410A.specificIsobaricHeatCapacityVap_Tv

Information

Function that calculates the specific isobaric heat capacity (cp) of R410A vapor based on temperature and specific volume.

The specific isobaric heat capacity is evaluated from the partial derivatives of the Martin-Hou equation of state.

References

F. de Monte. (2002). Calculation of thermodynamic properties of R407C and R410A by the Martin-Hou equation of state, part I: theoretical development. International Journal of Refrigeration. 25. 306-313.

Thermodynamic properties of DuPont Suva 410A: https://www.chemours.com/Refrigerants/en_US/assets/downloads/h64423_Suva410A_thermo_prop_si.pdf

Interface

function specificIsobaricHeatCapacityVap_Tv
  input Modelica.Units.SI.Temperature T "Temperature of refrigerant";
  input Modelica.Units.SI.SpecificVolume v "Specific volume of refrigerant";
  output Modelica.Units.SI.SpecificHeatCapacity cp "Specific isobaric heat capacity";
end specificIsobaricHeatCapacityVap_Tv;

Revisions


Generated at 2024-04-28T18:16:21Z by OpenModelicaOpenModelica 1.22.3 using GenerateDoc.mos