modelNoCooling
Placeholder to disable cooling
Extends from PartialChillerCycle (Partial model of refrigerant cycle used for chiller applications).
Information
Using this model, the chiller will always be off. This option is mainly used to avoid warnings about partial model which must be replaced.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| String | devIde (from PartialRefrigerantCycle) | "" | Indicates the data source, used to warn users about different vapor compression devices in reversible models |
| Boolean | useInChi (from PartialChillerCycle) | =false to indicate that this model is used as a heat pump | |
| Nominal condition | |||
| Modelica.Units.SI.Power | PEle_nominal (from PartialRefrigerantCycle) | Nominal electrical power consumption | |
| Modelica.Units.SI.Temperature | TCon_nominal (from PartialRefrigerantCycle) | Nominal temperature at secondary condenser side | |
| Modelica.Units.SI.Temperature | TEva_nominal (from PartialRefrigerantCycle) | Nominal temperature at secondary evaporator side | |
| Modelica.Units.SI.HeatFlowRate | QCoo_flow_nominal (from PartialChillerCycle) | Nominal cooling capacity | |
| Advanced › Medium properties | |||
| Modelica.Units.SI.SpecificHeatCapacity | cpCon (from PartialRefrigerantCycle) | Evaporator medium specific heat capacity | |
| Modelica.Units.SI.SpecificHeatCapacity | cpEva (from PartialRefrigerantCycle) | Evaporator medium specific heat capacity | |
Connectors
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Blocks.Interfaces.RealOutput | PEle (from PartialRefrigerantCycle) | Electrical Power consumed by the device | |
| Modelica.Blocks.Interfaces.RealOutput | QCon_flow (from PartialRefrigerantCycle) | Heat flow rate through condenser | |
| Buildings.Fluid.HeatPumps.ModularReversible.BaseClasses.RefrigerantMachineControlBus | sigBus (from PartialRefrigerantCycle) | Bus-connector | |
| Modelica.Blocks.Interfaces.RealOutput | QEva_flow (from PartialRefrigerantCycle) | Heat flow rate through evaporator |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Buildings.Fluid.HeatPumps.ModularReversible.RefrigerantCycle.Frosting.NoFrosting | iceFacCal (from PartialRefrigerantCycle) | ||
| Modelica.Blocks.Math.Add | redQCon (from PartialRefrigerantCycle) | Reduce heat flow to the condenser based on the reduction to the evaporator | |
| Modelica.Blocks.Math.Product | proRedQEva (from PartialRefrigerantCycle) | Reduce heat flow to the evaporator based on the icing factor | |
| Modelica.Blocks.Sources.Constant | const | Zero energy flows |
Revisions
-
October 2, 2022 by Fabian Wuellhorst:
First implementation (see issue #1576)