modelCase630

Case 620, but with added overhang and sidefins

Extends from Buildings.ThermalZones.ISO13790.Validation.BESTEST.Cases6xx.Case600 (Case 600FF, but with dual-setpoint for heating and cooling).

Information

This model is the case 630 of the BESTEST validation suite. Case 630 differs from case 620 in that windows on the west and east walls have an overhang and side fins.

Implementation

The shading reduction factor was set to 0.846 for overhang and 0.915 for side fins. These values were calculated based on Table G.6 and Table G.7 of the ISO13790 standard.

Components

TypeNameDefaultDescription
Modelica.Blocks.Math.SumsumHeaCoo (from Case600)Sum of heating and cooling heat flow rate
Modelica.Thermal.HeatTransfer.Sources.PrescribedHeatFlowpreHeaCoo (from Case600)Prescribed heat flow for heating and cooling
Modelica.Blocks.Math.GaingaiHea (from Case600)Gain for heating
Buildings.Controls.Continuous.LimPIDconHeaPID (from Case600)Controller for heating
Modelica.Blocks.Sources.CombiTimeTableTSetHea (from Case600)Setpoint for heating
Modelica.Blocks.Routing.Multiplex2multiplex2 (from Case600)
Modelica.Blocks.Math.GaingaiCoo (from Case600)Gain for cooling
Buildings.Controls.Continuous.LimPIDconCooPID (from Case600)Controller for cooling
Modelica.Blocks.Continuous.IntegratorECoo (from Case600)Cooling energy in Joules
Buildings.ThermalZones.ISO13790.Zone5R1C.ZoneHVACzonHVAC (from Case600)
Modelica.Blocks.Sources.ConstantintGai (from Case600)Internal heat gains
Buildings.BoundaryConditions.WeatherData.ReaderTMY3weaDat (from Case600)Weather data
Modelica.Blocks.Continuous.IntegratorEHea (from Case600)Cooling energy in Joules
Buildings.Controls.OBC.CDL.Reals.MovingAveragePHea (from Case600)Hourly averaged heating power
Buildings.Controls.OBC.CDL.Reals.MovingAveragePCoo (from Case600)Hourly averaged cooling power
Modelica.Blocks.Sources.CombiTimeTableTSetCoo (from Case600)Setpoint for cooling
Modelica.Blocks.Sources.ConstantlatGai (from Case600)Internal heat gains

Revisions

  • Mar 2, 2024, by Alessandro Maccarini:
    First implementation.