modelCase650FF
Extends from Buildings.ThermalZones.ISO13790.Validation.BESTEST.Cases6xx.Case600FF (Basic test with light-weight construction and free floating temperature).
Information
This model is used for the test case 650FF of the BESTEST validation suite. Case 650FF is identical to case 650, except that there is no heating and no cooling.
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Buildings.ThermalZones.ISO13790.Zone5R1C.ZoneHVAC | zonHVAC (from Case600FF) | Thermal zone | |
| Buildings.BoundaryConditions.WeatherData.ReaderTMY3 | weaDat (from Case600FF) | Weather data | |
| Modelica.Blocks.Sources.Constant | intGai (from Case600FF) | Internal heat gains | |
| Buildings.Controls.OBC.CDL.Reals.MovingAverage | TRooHou (from Case600FF) | Continuous mean of room air temperature | |
| Buildings.Controls.OBC.CDL.Reals.MovingAverage | TRooAnn (from Case600FF) | Continuous mean of room air temperature | |
| Modelica.Blocks.Sources.Constant | latGai (from Case600FF) | Internal heat gains | |
| Buildings.Fluid.Sensors.Density | senDen | ||
| Modelica.Blocks.Math.Product | product1 | Product to compute infiltration mass flow rate | |
| Modelica.Blocks.Sources.CombiTimeTable | vent | Ventilation air flow rate | |
| Buildings.Fluid.Sources.MassFlowSource_T | sinInf | Sink model for air infiltration | |
| Buildings.Fluid.Sources.Outside | out |
Revisions
-
May 3, 2024, Alessandro Maccarini:
First implementation.