modelCase685
Extends from Buildings.ThermalZones.ISO13790.Validation.BESTEST.Cases6xx.Case600 (Case 600FF, but with dual-setpoint for heating and cooling).
Information
This model is the case 685 of the BESTEST validation suite. Case 685 differs from case 600 in that it has single heating and cooling setpoint.
- Heat = on if zone temperature is below 20°C
- Cool = on if zone temperature is above 20°C
Components
Revisions
-
May 3, 2024, by Alessandro Maccarini:
First implementation.