modelNTU_L3_standalone

A three-zonal NTU cell model with internally calculated zone size

Extends from ClaRa.Basics.Icons.NTU, ClaRa.Basics.Icons.ComplexityLevel (Displays the complexity level inside model icon ).

Information

For detailed model documentation please consult the html-documentation shipped with ClaRa.

 


Authorship and Copyright Statement for original (initial) Contribution

Author:

DYNCAP/DYNSTART development team, Copyright © 2011-2024.

References:

For references please consult the html-documentation shipped with ClaRa.

Remarks:

This component was developed by ClaRa development team under the 3-clause BSD License.

Acknowledgements:

ClaRa originated from the collaborative research projects DYNCAP and DYNSTART. Both research projects were supported by the German Federal Ministry for Economic Affairs and Energy (FKZ 03ET2009 and FKZ 03ET7060).

CLA:

The author(s) have agreed to ClaRa CLA, version 1.0. See https://claralib.com/pdf/CLA.pdf

By agreeing to ClaRa CLA, version 1.0 the author has granted the ClaRa development team a permanent right to use and modify his initial contribution as well as to publish it or its modified versions under the 3-clause BSD License.

The ClaRa development team consists of the following partners:

TLK-Thermo GmbH (Braunschweig, Germany)

XRG Simulation GmbH (Hamburg, Germany).

Parameters

TypeNameDefaultDescription
Modelica.Units.SI.ThermalResistanceHR_nomnTU.HR_nomNominal conductive heat resistance
Fundamental Definitions
TILMedia.VLEFluid.Types.BaseVLEFluidmedium_shellsimCenter.fluid1Medium of shell side
TILMedia.VLEFluid.Types.BaseVLEFluidmedium_tubessimCenter.fluid1Medium of tubes side
BooleanouterPhaseChangetrueTrue, if phase change may occur at outer side
Geometry
IntegerN_t1Number of tubes in one pass
IntegerN_p1Number of passes
Units.LengthlengthTube length (for one pass)
Units.Lengthradius_iInner radius of tube
Units.Lengthradius_oOuter radius of tube
Realmass_struc0Mass of inner structure elements, additional to the tubes itself
RealCF_geo1Correction coefficient due to fins etc.
Initialisation
IntegerinitOption0Thermal initialisation
Units.Temperature[3]T_w_i_startones(3)*293.15Initial temperature at inner phase
Units.Temperature[3]T_w_o_startones(3)*293.15Initial temperature at outer phase
IntegerinitOption_yps3Volumetric initialisation
Real[2]yps_start{0, 0}Initial area fraction 1phase | 2phase
Expert Settings
Realgain_eff1Avoid effectiveness > 1, high gain_eff leads to stricter observation but may cause numeric errors
SI.TimeTau_stab0.1Time constant for numeric stabilisation w.r.t. heat flow rates
BooleanshowExpertSummaryfalseTrue,if expert summaries shall be shown

Connectors

TypeNameDefaultDescription
ClaRa.Basics.Interfaces.HeatPort_a[3]outerPhaseouter side of cylinder
ClaRa.Basics.Interfaces.HeatPort_a[3]innerPhaseinner side of cylinder

Components

TypeNameDefaultDescription
ClaRa.SimCentersimCenter
Stringcomplexity (from ComplexityLevel)"??"
Units.Pressurep_oPressure at outer side
Units.Pressurep_iPressure at inner side
Units.EnthalpyMassSpecifich_i_inletInlet enthalpy of inner flow
Units.EnthalpyMassSpecifich_o_inletInlet enthalpy of outer flow
Units.MassFlowRatem_flow_iMass flow rate of inner side
Units.MassFlowRatem_flow_oMass flow rate of outer side
ClaRa.Basics.Units.MassFraction[medium_tubes.nc - 1]xi_iMass fraction at outer side
ClaRa.Basics.Units.MassFraction[medium_shell.nc - 1]xi_oMass fraction at outer side
Units.CoefficientOfHeatTransfer[3]alpha_iCoefficient of heatTransfer for inner side for regions |A|B|C|
Units.CoefficientOfHeatTransfer[3]alpha_oCoefficient of heatTransfer for outer side for regions |A|B|C|
Summarysummary

Contents

NameDescription
Material
HeatExchangerType
HeatCapacityAveraging
Summary
ECom

Revisions

For revisions please consult the html-documentation shipped with ClaRa.