.ClaRa.Components.BoundaryConditions.PrescribedMassFlowVLE

Information

This very simple model provides a pressure drop which is proportional to the flowrate and to the opening input, without computing any fluid property. It can be used for testing purposes, when a simple model of a variable pressure loss is needed.

A medium model must be nevertheless be specified, so that the fluid ports can be connected to other components using the same medium model.

The model is adiabatic (no heat losses to the ambient) and neglects changes in kinetic energy from the inlet to the outlet.

For detailed model documentation please consult the html-documentation shipped with ClaRa.

 


Authorship and Copyright Statement for original (initial) Contribution

Author:

DYNCAP/DYNSTART development team, Copyright © 2011-2024.

References:

For references please consult the html-documentation shipped with ClaRa.

Remarks:

This component was developed by ClaRa development team under the 3-clause BSD License.

Acknowledgements:

ClaRa originated from the collaborative research projects DYNCAP and DYNSTART. Both research projects were supported by the German Federal Ministry for Economic Affairs and Energy (FKZ 03ET2009 and FKZ 03ET7060).

CLA:

The author(s) have agreed to ClaRa CLA, version 1.0. See https://claralib.com/pdf/CLA.pdf

By agreeing to ClaRa CLA, version 1.0 the author has granted the ClaRa development team a permanent right to use and modify his initial contribution as well as to publish it or its modified versions under the 3-clause BSD License.

The ClaRa development team consists of the following partners:

TLK-Thermo GmbH (Braunschweig, Germany)

XRG Simulation GmbH (Hamburg, Germany).

Contents

NameDescription
 Summary

Revisions


Generated at 2024-11-23T19:25:52Z by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos