modelQuadratic_EN60534_incompressible

Quadratic | Kv definition | choked flow | incompressible |EN60534

Extends from ClaRa.Components.VolumesValvesFittings.Valves.Fundamentals.GenericPressureLoss, ClaRa.Components.VolumesValvesFittings.Valves.Fundamentals.Quadratic_EN60534_incompressible_base (Quadratic|Kv definition | supercritical flow | incompressible |EN60534).

Information

For detailed model documentation please consult the html-documentation shipped with ClaRa.

 


Authorship and Copyright Statement for original (initial) Contribution

Author:

DYNCAP/DYNSTART development team, Copyright © 2011-2024.

References:

For references please consult the html-documentation shipped with ClaRa.

Remarks:

This component was developed by ClaRa development team under the 3-clause BSD License.

Acknowledgements:

ClaRa originated from the collaborative research projects DYNCAP and DYNSTART. Both research projects were supported by the German Federal Ministry for Economic Affairs and Energy (FKZ 03ET2009 and FKZ 03ET7060).

CLA:

The author(s) have agreed to ClaRa CLA, version 1.0. See https://claralib.com/pdf/CLA.pdf

By agreeing to ClaRa CLA, version 1.0 the author has granted the ClaRa development team a permanent right to use and modify his initial contribution as well as to publish it or its modified versions under the 3-clause BSD License.

The ClaRa development team consists of the following partners:

TLK-Thermo GmbH (Braunschweig, Germany)

XRG Simulation GmbH (Hamburg, Germany).

Parameters

TypeNameDefaultDescription
RealKvs (from Quadratic_EN60534_incompressible_base)if paraOption == 1 then Kvs_in else if paraOption == 2 then 3600*m_flow_nom/rho_in_nom*sqrt(rho_in_nom/1000*1e5/Delta_p_nom) else A_cross*sqrt(2/zeta)*sqrt(1e5/1000)*3600Actual value of Kvs_in depending on parametrisation option
Valve Geometry
Realdiameter_inlet (from Quadratic_EN60534_incompressible_base)10Inlet fitting's diameter
Realdiameter_valve (from Quadratic_EN60534_incompressible_base)10Valve diameter
Realdiameter_outlet (from Quadratic_EN60534_incompressible_base)10Outlet fitting's diameter
RealF_L (from Quadratic_EN60534_incompressible_base)0.75Liquid pressure recovery factor when no reducers are installed
Valve Characteristics
IntegerparaOption (from Quadratic_EN60534_incompressible_base)1Type of parametrisation
Real[:,:]CL_valve (from Quadratic_EN60534_incompressible_base)[0, 0; 1, 1]Effective apperture as function of valve position in p.u.
RealKvs_in (from Quadratic_EN60534_incompressible_base)1Flow Coefficient at nominal opening (Delta_p_nom = 1e5 Pa, rho_nom=1000 kg/m^3(cold water))
SI.MassFlowRatem_flow_nom (from Quadratic_EN60534_incompressible_base)Kvs_in/1000/3600Nominal mass flowrate at full opening
SI.PressureDelta_p_nom (from Quadratic_EN60534_incompressible_base)1e5Nominal pressure difference for Kv definition
SI.DensityMassSpecificrho_in_nom (from Quadratic_EN60534_incompressible_base)1000Nominal density for Kv definition
Realzeta (from Quadratic_EN60534_incompressible_base)100Pressure Loss coefficient
SI.AreaA_cross (from Quadratic_EN60534_incompressible_base)1Valve inlet cross section
Expert Settings
SI.PressureDelta_p_eps (from Quadratic_EN60534_incompressible_base)100Small pressure difference for linearisation around zeor flow

Components

TypeNameDefaultDescription
BooleancheckValve (from GenericPressureLoss)
BooleanuseHomotopy (from GenericPressureLoss)
Basics.Units.MassFlowRatem_flow (from GenericPressureLoss)
RealflowIsChoked (from GenericPressureLoss)1 if flow is choked, 0 if not
RealPR_choked (from GenericPressureLoss)Pressure ratio at which choking occurs
ClaRa.Components.VolumesValvesFittings.Valves.Fundamentals.IComiCom (from Quadratic_EN60534_incompressible_base)
Realaperture_ (from Quadratic_EN60534_incompressible_base)Effective apperture
SI.PressureDifferenceDelta_p (from Quadratic_EN60534_incompressible_base)Pressure difference p_in - p_out
RealKv (from Quadratic_EN60534_incompressible_base)Flow Coefficient (Delta_p_nom = 1e5 Pa, rho_nom=1000 kg/m^3(cold water))
SI.PressureDelta_p_choke (from Quadratic_EN60534_incompressible_base)Pressure difference at which choking occurs, always positive i.e. independent of flow direction
BooleannormIsValid (from Quadratic_EN60534_incompressible_base)Kvs/0.865/diameter_valve^2 < 0.047Validity of DIN
Modelica.Blocks.Tables.CombiTable1DvValveCharacteristics (from Quadratic_EN60534_incompressible_base)
RealF_P (from Quadratic_EN60534_incompressible_base)1/sqrt(1 + (((1 - diameter_valve^4/diameter_inlet^4) - (1 - diameter_valve^4/diameter_outlet^4) + 0.5*(1 - (diameter_valve/diameter_inlet)^2)^2 + (1 - (diameter_valve/diameter_outlet)^2)^2)*Kv^2/diameter_valve^4)/K1)Pipe geometry correction factor

Revisions

For revisions please consult the html-documentation shipped with ClaRa.