modelSwitchOffLogicSide1
Manage switch-off logic for side 1 of a quadripole
Information
Handles a predefinite number of switch-off signals and sets running to false as soon as one signal is set to true.
Parameters
| Type | Name | Default | Description |
| Integer | NbSwitchOffSignalsSide1 | | Number of switch-off signals to take into account in inputs |
| Boolean | SwitchOffSignal1Side10 | false | Initial switch-off signal 1 for side 1 of the quadripole |
| Boolean | SwitchOffSignal2Side10 | false | Initial switch-off signal 2 for side 1 of the quadripole |
| Boolean | SwitchOffSignal3Side10 | false | Initial switch-off signal 3 for side 1 of the quadripole |
| Boolean | RunningSide10 | if NbSwitchOffSignalsSide1 >= 3 then not (SwitchOffSignal1Side10 or SwitchOffSignal2Side10 or SwitchOffSignal3Side10) elseif NbSwitchOffSignalsSide1 >= 2 then not (SwitchOffSignal1Side10 or SwitchOffSignal2Side10) else not SwitchOffSignal1Side10 | Indicates if the component is initially running on side 1 or not |