| Types.PerUnit | K | | Governor gain (reciprocal of droop) |
| Types.PerUnit | K1 | | Fraction of HP shaft power after first boiler pass |
| Types.PerUnit | K2 | | Fraction of LP shaft power after first boiler pass |
| Types.PerUnit | K3 | | Fraction of HP shaft power after second boiler pass |
| Types.ActivePowerPu | PMaxPu | | Maximum valve opening in pu (base PNomTurb) |
| Types.ActivePowerPu | PMinPu | | Minimum valve opening in pu (base PNomTurb) |
| Types.ActivePowerPu | PrMaxPu | | Maximum pressure in reheater in pu (base PNomTurb) |
| Types.Time | t1 | | Governor lag time constant in s |
| Types.Time | t2 | | Governor lead time constant in s |
| Types.Time | t3 | | Valve positioner time constant in s |
| Types.Time | t4 | | Inlet piping / steam bowl time constant in s |
| Types.Time | t5 | | Time constant of second boiler pass (reheater) in s |
| Types.Time | t6 | | Time constant of crossover of third boiler pass in s |
| Types.Time | tA | | Time to close intercept valve in s |
| Types.Time | tB | | Time until intercept valve starts to reopen in s |
| Types.Time | tC | | Time until intercept valve is fully open in s |
| Types.PerUnit | Uc | | Maximum valve closing velocity in pu/s (base PNomTurb) |
| Types.PerUnit | Uo | | Maximum valve opening velocity in pu/s (base PNomTurb) |
| String | FValveTableName | | Name of table in text file for flow rate as a function of pressure |
| String | TablesFile | | Text file that contains the table for the function |
| Types.ActivePowerPu | Pm0Pu | | Initial mechanical power in pu (base PNomTurb) |
| Types.ActivePowerPu | Pr0Pu | | Initial pressure in reheater in pu (base PNomTurb) |