modelHvdcPTanPhi_INIT
Initialisation model of P/tan(Phi) HVDC link
Extends from AdditionalIcons.Init, BaseClasses_INIT.BaseHVDC_INIT (Base initialization model for HVDC link).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Types.ActivePowerPu | P10Pu (from BaseHVDC_INIT) | Start value of active power at terminal 1 in pu (base SnRef) (receptor convention) | |
| Types.ReactivePowerPu | Q10Pu (from BaseHVDC_INIT) | Start value of reactive power at terminal 1 in pu (base SnRef) (receptor convention) | |
| Types.VoltageModulePu | U10Pu (from BaseHVDC_INIT) | Start value of voltage amplitude at terminal 1 in pu (base UNom) | |
| Types.Angle | UPhase10 (from BaseHVDC_INIT) | Start value of voltage angle at terminal 1 in rad | |
| Types.ActivePowerPu | P20Pu (from BaseHVDC_INIT) | Start value of active power at terminal 2 in pu (base SnRef) (receptor convention) | |
| Types.ReactivePowerPu | Q20Pu (from BaseHVDC_INIT) | Start value of reactive power at terminal 2 in pu (base SnRef) (receptor convention) | |
| Types.VoltageModulePu | U20Pu (from BaseHVDC_INIT) | Start value of voltage amplitude at terminal 2 in pu (base UNom) | |
| Types.Angle | UPhase20 (from BaseHVDC_INIT) | Start value of voltage angle at terminal 2 in rad | |
| Real | CosPhi1Ref0 | Start value of cos(Phi) regulation set point at terminal 1 | |
| Real | CosPhi2Ref0 | Start value of cos(Phi) regulation set point at terminal 2 | |
| Types.ActivePowerPu | P1RefSetPu | Start value of active power reference at terminal 1 in pu (base SnRef) (receptor convention) |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Types.ComplexCurrentPu | i10Pu (from BaseHVDC_INIT) | Start value of complex current at terminal 1 in pu (base UNom, SnRef) (receptor convention) | |
| Types.ActivePowerPu | P1Ref0Pu (from BaseHVDC_INIT) | Start value of active power reference at terminal 1 in pu (base SnRef) (receptor convention) | |
| Types.ComplexApparentPowerPu | s10Pu (from BaseHVDC_INIT) | Start value of complex apparent power at terminal 1 in pu (base SnRef) (receptor convention) | |
| Types.Angle | Theta10 (from BaseHVDC_INIT) | Start value of angle of the voltage at terminal 1 in rad | |
| Types.ComplexVoltagePu | u10Pu (from BaseHVDC_INIT) | Start value of complex voltage at terminal 1 in pu (base UNom) | |
| Types.ComplexCurrentPu | i20Pu (from BaseHVDC_INIT) | Start value of complex current at terminal 2 in pu (base UNom, SnRef) (receptor convention) | |
| Types.ComplexApparentPowerPu | s20Pu (from BaseHVDC_INIT) | Start value of complex apparent power at terminal 2 in pu (base SnRef) (receptor convention) | |
| Types.Angle | Theta20 (from BaseHVDC_INIT) | Start value of angle of the voltage at terminal 2 in rad | |
| Types.ComplexVoltagePu | u20Pu (from BaseHVDC_INIT) | Start value of complex voltage at terminal 2 in pu (base UNom) | |
| Real | TanPhi1Ref0 | Start value of tan(Phi) regulation set point at terminal 1 | |
| Real | TanPhi2Ref0 | Start value of tan(Phi) regulation set point at terminal 2 |