modelHvdcPVDanglingDiagramPQ_INIT

Initialisation model of PV HVDC link with a PQ diagram and with terminal 1 only

Extends from AdditionalIcons.Init, BaseClasses_INIT.BaseHVDC_INIT (Base initialization model for HVDC link), BaseClasses_INIT.BaseQStatusDangling_INIT (Base initialization model for QStatus at terminal 1), BaseClasses_INIT.BaseDiagramPQDangling_INIT (Base initialization model for PQ diagram at terminal 1), BaseClasses_INIT.BasePV_INIT (Base initialization model for PV HVDC).

Parameters

TypeNameDefaultDescription
Types.ActivePowerPuP10Pu (from BaseHVDC_INIT)Start value of active power at terminal 1 in pu (base SnRef) (receptor convention)
Types.ReactivePowerPuQ10Pu (from BaseHVDC_INIT)Start value of reactive power at terminal 1 in pu (base SnRef) (receptor convention)
Types.VoltageModulePuU10Pu (from BaseHVDC_INIT)Start value of voltage amplitude at terminal 1 in pu (base UNom)
Types.AngleUPhase10 (from BaseHVDC_INIT)Start value of voltage angle at terminal 1 in rad
Types.ActivePowerPuP20Pu (from BaseHVDC_INIT)Start value of active power at terminal 2 in pu (base SnRef) (receptor convention)
Types.ReactivePowerPuQ20Pu (from BaseHVDC_INIT)Start value of reactive power at terminal 2 in pu (base SnRef) (receptor convention)
Types.VoltageModulePuU20Pu (from BaseHVDC_INIT)Start value of voltage amplitude at terminal 2 in pu (base UNom)
Types.AngleUPhase20 (from BaseHVDC_INIT)Start value of voltage angle at terminal 2 in rad
Types.ReactivePowerPuQInj1Max0Pu (from BaseDiagramPQDangling_INIT)Start value of the maximum reactive power in pu (base SnRef) (generator convention) at terminal 1
Types.ReactivePowerPuQInj1Min0Pu (from BaseDiagramPQDangling_INIT)Start value of the minimum reactive power in pu (base SnRef) (generator convention) at terminal 1
Types.ActivePowerPuP1RefSetPu (from BasePV_INIT)Start value of active power reference at terminal 1 in pu (base SnRef) (receptor convention)
Types.ReactivePowerQ1Nom (from BasePV_INIT)Nominal reactive power in Mvar at terminal 1
Types.VoltageModulePuU1Ref0Pu (from BasePV_INIT)Start value of the voltage regulation set point in pu (base UNom) at terminal 1

Components

TypeNameDefaultDescription
Types.ComplexCurrentPui10Pu (from BaseHVDC_INIT)Start value of complex current at terminal 1 in pu (base UNom, SnRef) (receptor convention)
Types.ActivePowerPuP1Ref0Pu (from BaseHVDC_INIT)Start value of active power reference at terminal 1 in pu (base SnRef) (receptor convention)
Types.ComplexApparentPowerPus10Pu (from BaseHVDC_INIT)Start value of complex apparent power at terminal 1 in pu (base SnRef) (receptor convention)
Types.AngleTheta10 (from BaseHVDC_INIT)Start value of angle of the voltage at terminal 1 in rad
Types.ComplexVoltagePuu10Pu (from BaseHVDC_INIT)Start value of complex voltage at terminal 1 in pu (base UNom)
Types.ComplexCurrentPui20Pu (from BaseHVDC_INIT)Start value of complex current at terminal 2 in pu (base UNom, SnRef) (receptor convention)
Types.ComplexApparentPowerPus20Pu (from BaseHVDC_INIT)Start value of complex apparent power at terminal 2 in pu (base SnRef) (receptor convention)
Types.AngleTheta20 (from BaseHVDC_INIT)Start value of angle of the voltage at terminal 2 in rad
Types.ComplexVoltagePuu20Pu (from BaseHVDC_INIT)Start value of complex voltage at terminal 2 in pu (base UNom)
BooleanlimUQDown10 (from BaseQStatusDangling_INIT)Whether the minimum reactive power limits are reached or not at terminal 1, start value
BooleanlimUQUp10 (from BaseQStatusDangling_INIT)Whether the maximum reactive power limits are reached or not at terminal 1, start value
QStatusq1Status0 (from BaseQStatusDangling_INIT)Start voltage regulation status of terminal 1: Standard, AbsorptionMax, GenerationMax
Types.ReactivePowerPuQInj10PuQNom (from BasePV_INIT)Reactive power at terminal 1 in pu (base Q1Nom) (generator convention)
Types.VoltageModulePuU1Ref0PuVar (from BasePV_INIT)Start value of the voltage regulation set point in pu (base UNom) at terminal 1