Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Types.ActivePowerPu | P10Pu (from BaseHVDC_INIT) | Start value of active power at terminal 1 in pu (base SnRef) (receptor convention) | |
| Types.ReactivePowerPu | Q10Pu (from BaseHVDC_INIT) | Start value of reactive power at terminal 1 in pu (base SnRef) (receptor convention) | |
| Types.VoltageModulePu | U10Pu (from BaseHVDC_INIT) | Start value of voltage amplitude at terminal 1 in pu (base UNom) | |
| Types.Angle | UPhase10 (from BaseHVDC_INIT) | Start value of voltage angle at terminal 1 in rad | |
| Types.ActivePowerPu | P20Pu (from BaseHVDC_INIT) | Start value of active power at terminal 2 in pu (base SnRef) (receptor convention) | |
| Types.ReactivePowerPu | Q20Pu (from BaseHVDC_INIT) | Start value of reactive power at terminal 2 in pu (base SnRef) (receptor convention) | |
| Types.VoltageModulePu | U20Pu (from BaseHVDC_INIT) | Start value of voltage amplitude at terminal 2 in pu (base UNom) | |
| Types.Angle | UPhase20 (from BaseHVDC_INIT) | Start value of voltage angle at terminal 2 in rad | |
| Types.PerUnit | LambdaPu | Lambda coefficient for the QRefUPu calculation in pu (base SNom, UNom) | |
| Boolean | ModeU1Set | Set mode of control on side 1 : if true, U mode, if false, Q mode | |
| Boolean | ModeU2Set | Set mode of control on side 2 : if true, U mode, if false, Q mode | |
| Types.PerUnit | RDcPu | Resistance of one cable of DC line in pu (base UDcNom, SnRef) | |
| Types.ApparentPowerModule | SNom | Injector nominal apparent power in MVA |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Types.ComplexCurrentPu | i10Pu (from BaseHVDC_INIT) | Start value of complex current at terminal 1 in pu (base UNom, SnRef) (receptor convention) | |
| Types.ActivePowerPu | P1Ref0Pu (from BaseHVDC_INIT) | Start value of active power reference at terminal 1 in pu (base SnRef) (receptor convention) | |
| Types.ComplexApparentPowerPu | s10Pu (from BaseHVDC_INIT) | Start value of complex apparent power at terminal 1 in pu (base SnRef) (receptor convention) | |
| Types.Angle | Theta10 (from BaseHVDC_INIT) | Start value of angle of the voltage at terminal 1 in rad | |
| Types.ComplexVoltagePu | u10Pu (from BaseHVDC_INIT) | Start value of complex voltage at terminal 1 in pu (base UNom) | |
| Types.ComplexCurrentPu | i20Pu (from BaseHVDC_INIT) | Start value of complex current at terminal 2 in pu (base UNom, SnRef) (receptor convention) | |
| Types.ComplexApparentPowerPu | s20Pu (from BaseHVDC_INIT) | Start value of complex apparent power at terminal 2 in pu (base SnRef) (receptor convention) | |
| Types.Angle | Theta20 (from BaseHVDC_INIT) | Start value of angle of the voltage at terminal 2 in rad | |
| Types.ComplexVoltagePu | u20Pu (from BaseHVDC_INIT) | Start value of complex voltage at terminal 2 in pu (base UNom) | |
| Types.PerUnit | Ip10Pu | Start value of active current at terminal 1 in pu (base SNom, UNom) (DC to AC) | |
| Types.PerUnit | Ip20Pu | Start value of active current at terminal 2 in pu (base SNom, UNom) (DC to AC) | |
| Types.PerUnit | Iq10Pu | Start value of reactive current at terminal 1 in pu (base SNom, UNom) (DC to AC) | |
| Types.PerUnit | Iq20Pu | Start value of reactive current at terminal 2 in pu (base SNom, UNom) (DC to AC) | |
| Boolean | ModeU10 | Initial mode of control on side 1 : if true, U mode, if false, Q mode | |
| Boolean | ModeU20 | Initial mode of control on side 2 : if true, U mode, if false, Q mode | |
| Types.ReactivePowerPu | PRef0Pu | Start value of reactive power reference in pu (base SNom) (DC to AC) | |
| Types.ReactivePowerPu | QRef10Pu | Start value of reactive power reference at terminal 1 in pu (base SNom) (DC to AC) | |
| Types.ReactivePowerPu | QRef20Pu | Start value of reactive power reference at terminal 2 in pu (base SNom) (DC to AC) | |
| Types.VoltageModulePu | UDc10Pu | Start value of DC voltage at terminal 1 in pu (base UDcNom) | |
| Types.VoltageModulePu | UDc20Pu | Start value of DC voltage at terminal 2 in pu (base UDcNom) | |
| Types.VoltageModulePu | UDcRef0Pu | Start value of DC voltage reference in pu (base UDcNom) | |
| Types.VoltageModulePu | URef10Pu | Start value of the voltage reference for the side 1 of the HVDC link in pu (base UNom) | |
| Types.VoltageModulePu | URef20Pu | Start value of the voltage reference for the side 1 of the HVDC link in pu (base UNom) |