blockvoltageLimit

Limit the range of a voltage signal with variable limits

Extends from Modelica.Blocks.Interfaces.SISO (Single Input Single Output continuous control block).

Information

The Limiter block passes its input signal as output signal as long as the input is within the upper and lower limits specified by the two additional inputs limit1 and limit2. If this is not the case, the corresponding limit is passed as output.

Parameters

TypeNameDefaultDescription
Booleanstrictfalse= true, if strict limits with noEvent(..)
BooleanlimitsAtInittrue= false, if limits are ignored during initialization (i.e., y=u)
Limiting data
SI.VoltageU_eff_maxVoltage limit of motor module

Connectors

TypeNameDefaultDescription
RealInputu (from SISO)Connector of Real input signal
RealOutputy (from SISO)Connector of Real output signal
Modelica.Blocks.Interfaces.RealInputu_dConnector of Real input signal used as maximum of input u