modelNominalLifeRating

Calculation of nominal life rating for ball screw (see A. Mannesmann)

Extends from Modelica.Blocks.Interfaces.SI2SO (2 Single Input / 1 Single Output continuous control block).

Information

This blocks computes output y as sum of the two input signals u1 and u2:

    y = k1*u1 + k2*u2;

Example:

     parameter:   k1= +2, k2= -3

  results in the following equations:

     y = 2 * u1 - 3 * u2

Parameters

TypeNameDefaultDescription
SI.ForceC_am50000Dynamic load rating
SI.ForceF_pr0.07*C_amPreload force

Connectors

TypeNameDefaultDescription
RealInputu1 (from SI2SO)Connector of Real input signal 1
RealInputu2 (from SI2SO)Connector of Real input signal 2
RealOutputy (from SI2SO)Connector of Real output signal

Components

TypeNameDefaultDescription
SI.ForceF_aAxial operation force
SI.ForceF_wOperation force with preload
SI.ForceF_w_mEffective operation force
SI.AngularVelocitywAngular velocity of ball screw
SI.AngularVelocityw_mAverage angular velocity
Realtemp_F
Realtemp_w
RealL_10Number of 10^6 revolution with 90 % life expectancy
SI.Conversions.NonSIunits.Time_hourL_hLife expectancy on 90 % level