modelHalfCoilPhysical

Parameters

TypeNameDefaultDescription
Physical data
Modelica.Units.SI.DiameterbasePipeDi0Internal diameter of the base pipe used
Modelica.Units.SI.AnglebasePipeAngleModelica.Constants.pisector of the full pipe used
Realnum0total number of spires
Modelica.Units.SI.Distancepath0distance between centers of coil spires in meters
BooleanisBottomJacketfalse
Modelica.Units.SI.DiameterlowerHalfCoilDiam0
Modelica.Units.SI.DiameterlargerHalfCoilDiam0

Components

TypeNameDefaultDescription
Modelica.Units.SI.DiameterHalfCoilDiamHalf coil diameter
Modelica.Units.SI.DistanceHalfCoilHeigth
Modelica.Units.SI.AreaSauxHTfree surface between active spires
Modelica.Units.SI.AreaSiActiveactive pipe internal surface
Modelica.Units.SI.AreaPathSectionInternal section of the tube. But not the flow section if double pipe
Modelica.Units.SI.DistancePathPerimeterInternal perimeter of the tube. But not the flow perimeter if double pipe
Modelica.Units.SI.DistanceLtotaltotal pipe length, as necessary for obtainning its total weight
Modelica.Units.SI.AreaSactiveHTinternal surface potentially active for heat transfer, due to partial perimeter usage