This example compares a time transient and a quasi static model of a multi phase induction machine.
At start time tOn
a transient and a quasi static multi phase voltage source are
connected to an induction machine. The machines starts from standstill, accelerating inertias
against load torque quadratic dependent on speed, finally reaching nominal speed.
imc.tauElectrical
: transient torqueimc.wMechanical
: transient speedimc.tauElectrical
against imc.wMechanical
: transient torque speed characteristicimcQS.tauElectrical
: quasi static torqueimcQS.wMechanical
: quasi static speedimcQS.tauElectrical
against imcQS.wMechanical
: quasi static torque speed characteristiccurrentRMSsensor.I
: quasi RMS stator current of transient machinecurrentRMSSensorQS.I
: RMS stator current of quasi static machineimc.stator.electroMagneticConverter.abs_Phi
: magnitude of stator flux of transient machineimcQS.stator.electroMagneticConverter.abs_Phi
: magnitude of stator flux of quasi static machine