This example investigates a quasi static model of a electrically excited synchronous machine. The electrically excited synchronous generators are connected to the grid and driven with constant speed. Since speed is slightly smaller than synchronous speed corresponding to mains frequency, rotor angle is very slowly increased. This allows to see several characteristics dependent on rotor angle.
The intention is to compare the results of the following simulation models in one plot:
ie = 0
ie = 2 A
ie = 10 A
ie = 19 A
smee.tauElectrical
against theta
: electromagnetic torque against rotor displacement anglesmee.abs_is[1]
against theta
: RMS stator current (of phase 1) against rotor displacement angleQ
against theta
: reactive power against rotor displacement anglesmee.is[1].im
against smee.is[1].im
: locus of stator fixed stator currentisr[1].im
against isr[1].re
: locus of rotor fixed stator current