modelReferenceState
Information
The choice of reference state is more or less arbitrary, there are at least three standard reference states:- International Institute of Refrigeration (IIR)
- at T=0°C and saturated liquid set h=200 kJ/kg and s=1 kJ/kgK
- American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE)
- at T=-40°C and saturated liquid set h=0 kJ/kg and s=0 kJ/kgK
- normal boiling point (NBP)
- at p=1 atm = 1.01325 bar and saturated liquid set h=0 kJ/kg and s=0 kJ/kgK
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| String | fileName | "ReferenceState_" + Medium.mediumName + ".csv" | |
| String | separator | ";" |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| Medium.ReferenceState | ref | Medium.ReferenceState.IIR | |
| Medium.SpecificEnthalpy | h_ref | ||
| Medium.SpecificEntropy | s_ref |
Contents
| Name | Description |
|---|---|