This model outputs the trace substance of the passing fluid.
The sensor is ideal, i.e., it does not influence the fluid.
If the parameter tau
is non-zero, then its output
is computed using a first order differential equation.
Setting tau=0
is not recommend. See
IBPSA.Fluid.Sensors.UsersGuide for an explanation.
-
January 26, 2016, by Michael Wetter:
Avoided assignment of CMed(nominal=0)
as this is
not allowed.
-
January 18, 2016 by Filip Jorissen:
Using parameter tauInv
since this now exists in
IBPSA.Fluid.Sensors.BaseClasses.PartialDynamicFlowSensor.
This is for
#372.
-
June 10, 2015, by Michael Wetter:
Reformulated assignment of s
and assert
statement. The reformulation of the assignment of s
was
done to allow a model check in non-pedantic mode.
This is for
issue 268.
-
May 22, 2015, by Michael Wetter:
Corrected wrong sensor signal if allowFlowReversal=false
.
For this setting, the sensor output was for the wrong flow direction.
This is for
issue 249.
-
September 10, 2013, by Michael Wetter:
Corrected syntax errors in setting nominal value for output signal
and for state variable.
This eliminates a compilation error in OpenModelica.
-
August 30, 2013, by Michael Wetter:
Added default value C_start=0
.
-
November 3, 2011, by Michael Wetter:
Moved der(C) := 0;
from the initial algorithm section to
the initial equation section
as this assignment does not conform to the Modelica specification.
-
June 3, 2011 by Michael Wetter:
Revised implementation to add dynamics in such a way that
the time constant increases as the mass flow rate tends to zero.
This significantly improves the numerics.
-
February 22, by Michael Wetter:
Improved code that searches for index of trace substance in medium model.
-
September 29, 2009, by Michael Wetter:
First implementation.
Generated at 2024-11-22T19:25:38Z
by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos