recordPvPanel
Describes a Photovoltaic panel by its 5 main parameters and some extra parameter
Extends from Modelica.Icons.MaterialProperty (Icon for property classes).
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| Modelica.Units.SI.ElectricCurrent | I_phr | Light current under reference conditions | |
| Modelica.Units.SI.ElectricCurrent | I_or | Diode reverse saturation current under reference conditions | |
| Modelica.Units.SI.Resistance | R_sr | Series resistance under reference conditions | |
| Modelica.Units.SI.Resistance | R_shr | Shunt resistance under reference conditions | |
| Modelica.Units.SI.ElectricPotential | V_tr | modified ideality factor under reference conditions | |
| Modelica.Units.SI.ElectricCurrent | I_scr | Short circuit current under reference conditions | |
| Modelica.Units.SI.ElectricPotential | V_ocr | Open circuit voltage under reference conditions | |
| Modelica.Units.SI.ElectricCurrent | I_mpr | Maximum power point current under reference conditions | |
| Modelica.Units.SI.ElectricPotential | V_mpr | Maximum power point voltage under reference conditions | |
| Modelica.Units.SI.LinearTemperatureCoefficient | kV | Temperature coefficient for open circuit voltage | |
| Modelica.Units.SI.LinearTemperatureCoefficient | kI | Temperature coefficient for short circuit current | |
| Modelica.Units.SI.Temperature | T_ref | Reference temperature in Kelvin |