HeatPort-only tabs system, without embedded pipe
Description
Discretized heat transfer model of a thermally activated
building layer. The model has 3 heatPorts:
- portCore: port to the embeddedPipe
model that computes the heat trransfer to the core of the thermally
activated layer
- port_a: heatPort for heat emission at the upper side of the
TABS
- port_b: heatPort for heat emission at the lower side of the
TABS
Assumptions and limitations
- Discretized model in n1 elements between the core and port_a,
and n2 layers between core and port_b
- No capacity lumped to the core of the thermally activated
layer.
Model use
- The geometry, material properties and floor surface is obtained
from a record, radSlaCha
- To control the discretization in more detail, regardless of
material properties, n1 and n2 can be specified specifically.
Validation
This component is validated together with the EmbeddedPipe. The
effect of discretization is shown in IDEAS.Thermal.Components.Examples.NakedTabsTester.
A specific report of this validation can be found in
IDEAS/Specifications/Thermal/ValidationEmbeddedPipeModels_20111006.pdf
Example (optional)
The Tabs model
shows the integration of an EmbeddedPipe and a NakedTabs.
- 2013 May, Roel De Coninck: documentation
- 2012 April, Roel De Coninck: rebasing on common
Partial_Emission
- 2011, Roel De Coninck: first version and validation
Generated at 2026-04-14T18:18:34Z by OpenModelicaOpenModelica 1.26.3 using