modelPVT_UI_Electrical_DayType1
Test model for Unglazed Rear-Insulated PVT Collector
Extends from Modelica.Icons.Example (Icon for runnable examples).
Information
See the documentation of IDEAS.Fluid.PVTCollectors.Validation.PVT_UI for details on the validation examples and usage.
Parameters
| Type | Name | Default | Description |
|---|---|---|---|
| String | pvtTyp | "Typ1" | |
| Modelica.Units.SI.Temperature | T_start | 30.65195319 + 273.15 | Initial temperature (from measurement data) |
| Real | eleLosFac | 0.09 | |
| Data.Uncovered.UI_Validation | datPvtCol |
Components
| Type | Name | Default | Description |
|---|---|---|---|
| IDEAS.Fluid.PVTCollectors.Validation.PVT_UI.PVTQuasiDynamicCollectorValidation | PvtCol | ||
| Modelica.Blocks.Sources.CombiTimeTable | meaDat | ||
| Modelica.Thermal.HeatTransfer.Celsius.ToKelvin | TFluKel | ||
| IDEAS.Fluid.Sources.Boundary_pT | sou | Outlet for water flow | |
| IDEAS.Fluid.Sources.MassFlowSource_T | bou | Inlet for water flow, at a prescribed flow rate and temperature | |
| Modelica.Blocks.Sources.RealExpression | meaPel | [W] | |
| Modelica.Blocks.Sources.RealExpression | UAbsFluid | [W/m2K] | |
| Modelica.Blocks.Sources.RealExpression | simPel | [W] |
Contents
| Name | Description |
|---|---|
| Medium model |
Revisions
-
July 7, 2025, by Lone Meertens:
First implementation PVT model. This is for #1436.