Test Case 8 of the VDI 6007 Part 1: Calculation of indoor air
temperature excited by a radiative and convective heat source for
room version S with two exterior walls. It is based on Test Case 5.
Boundary conditions
- daily profile for outdoor air temperature in hourly steps
- daily profile for solar radiation on the exterior wall
- daily profile for solar radiation through the windows in hourly
steps
- sunblind closes at >100 W/m2
- no long-wave radiation exchange between exterior wall, windows
and ambient environment
This test validates reaction of indoor air
temperature at mixed internal gains and outdoor impacts including
solar radiation on exterior walls.
-
July 11, 2019, by Katharina Brinkmann:
Renamed alphaWall
to hConWall
-
July 7, 2016, by Moritz Lauster:
Added automatic check against validation thresholds.
-
January 11, 2016, by Moritz Lauster:
Implemented.
Generated at 2024-12-22T19:25:51Z