modelCounterCurrentHeatExchangerEquations_N_640

Extends from ScalableTestSuite.Thermal.HeatExchanger.ScaledExperiments.CounterCurrentHeatExchangerEquations_N_10.

Parameters

TypeNameDefaultDescription
SIunits.LengthL (from CounterCurrentHeatExchangerEquations)length of the channels
IntegerN (from CounterCurrentHeatExchangerEquations)2number of nodes
SIunits.MassFlowRatewB (from CounterCurrentHeatExchangerEquations)mass flow rate of fluid B
SIunits.AreaareaA (from CounterCurrentHeatExchangerEquations)cross sectional area of channel A
SIunits.AreaareaB (from CounterCurrentHeatExchangerEquations)cross sectional area of channel B
SIunits.DensityrhoA (from CounterCurrentHeatExchangerEquations)density of fluid A
SIunits.DensityrhoB (from CounterCurrentHeatExchangerEquations)density of fluid B
SIunits.SpecificHeatCapacitycpA (from CounterCurrentHeatExchangerEquations)specific heat capacity of fluid A
SIunits.SpecificHeatCapacitycpB (from CounterCurrentHeatExchangerEquations)specific heat capacity of fluid B
SIunits.SpecificHeatCapacitycpW (from CounterCurrentHeatExchangerEquations)specific heat capacity of the wall
SIunits.CoefficientOfHeatTransfergammaA (from CounterCurrentHeatExchangerEquations)heat transfer coefficient of fluid A
SIunits.CoefficientOfHeatTransfergammaB (from CounterCurrentHeatExchangerEquations)heat transfer coefficient of fluid B
SIunits.Lengthomega (from CounterCurrentHeatExchangerEquations)perimeter
SIunits.Lengthl (from CounterCurrentHeatExchangerEquations)L/(N - 1)length of the each wall segment

Components

TypeNameDefaultDescription
SIunits.MassFlowRatewA (from CounterCurrentHeatExchangerEquations)mass flow rate of fluid A
SIunits.HeatFlowRate[N - 1]QA (from CounterCurrentHeatExchangerEquations)heat flow rate of fluid A in the segments
SIunits.HeatFlowRate[N - 1]QB (from CounterCurrentHeatExchangerEquations)heat flow rate of fluid B in the segments
SIunits.Temperature[N]TA (from CounterCurrentHeatExchangerEquations)temperature nodes on channel A
SIunits.Temperature[N]TB (from CounterCurrentHeatExchangerEquations)temperature nodes on channel B
SIunits.Temperature[N - 1]TAtilde (from CounterCurrentHeatExchangerEquations)temperature states on channel A
SIunits.Temperature[N - 1]TBtilde (from CounterCurrentHeatExchangerEquations)temperature states on channel B
SIunits.Temperature[N - 1]TW (from CounterCurrentHeatExchangerEquations)temperatures on the wall segments
SIunits.HeatFlowRateQtotA (from CounterCurrentHeatExchangerEquations)total heat flow rate of fluid A
SIunits.HeatFlowRateQtotB (from CounterCurrentHeatExchangerEquations)total heat flow rate of fluid B