This example shows a comparison of a multi-segment OLine model with the distributed-parameter line model TLine.
If resistances and conductances are negligible, with OLine the results should become closer and closer as the number of segments increases.
Suggested tests:
Use the model as it is (it has firstOrder.T=1e-9
s) and compare R1.v
, R5.v
, R50.v
, Rdistr.v
: Rdistr.v
is the ideal voltage of the receiving-end resistor for a lossless line, while the others are approximations with 1, 5, 50 cascaded segment models.
The step in this case is nearly ideal, and therefore is a very tough test for cascaded segments, and in fact they are not very good in approximating the real line behaviour.
Repeat the simulation using firstOrder.T=20e-6