.Modelica.Electrical.Machines.Examples.DCMachines.DCEE_Start

Information

Test example: Electrically separate excited DC machine started with an armature voltage ramp
A voltage ramp is applied to the armature, causing the DC machine to start, and accelerating inertias.
At time tStep a load step is applied.
Simulate for 2 seconds and plot (versus time): Default machine parameters of model DC_ElectricalExcited are used.