.Modelica.Magnetic.FundamentalWave.Examples.BasicMachines.InductionMachines.IMC_withLosses

Information

Current I_sim I_meas
Speed w_sim w_meas
Power factor pf_sim pf_meas
Efficiency eff_sim eff_meas

Machine parameters are taken from a standard 18.5 kW 400 V 50 Hz motor, simulation results are compared with measurements.

Nominal stator current 32.85 A
Power factor 0.898
Speed 1462.5 rpm
Electrical input 20,443.95 W
Stator copper losses 770.13 W
Stator core losses 410.00 W
Rotor copper losses 481.60 W
Stray load losses 102.22 W
Friction losses 180.00 W
Mechanical output 18,500.00 W
Efficiency 90.49 %
Nominal torque 120.79 Nm

Stator resistance per phase 0.56 Ω
Temperature coefficient copper
Reference temperature 20 °C
Operation temperature 90 °C
Stator leakage reactance at 50 Hz 1.52 Ω
Main field reactance at 50 Hz 66.40 Ω
Rotor leakage reactance at 50 Hz 2.31 Ω
Rotor resistance per phase 0.42 Ω
Temperature coefficient aluminium
Reference temperature 20 °C
Operation temperature 90 °C

See:
Anton Haumer, Christian Kral, Hansjörg Kapeller, Thomas Bäuml, Johannes V. Gragger
The AdvancedMachines Library: Loss Models for Electric Machines
Modelica 2009, 7th International Modelica Conference


Generated at 2024-11-23T19:25:52Z by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos