- Simulate for 5 seconds: The machine is started at nominal speed, flux is build up in the machine.
- Continue the simulation for additional 5 seconds: Subsequently a load ramp is applied.
- Compare by plotting versus Pmech:
Current | I_sim | I_meas |
Speed | w_sim | w_meas |
Power factor | pf_sim | pf_meas |
Efficiency | eff_sim | eff_meas |
Machine parameters are taken from a standard 18.5 kW 400 V 50 Hz motor, simulation results are compared with measurements.
Nominal stator current | 32.85 | A |
Power factor | 0.898 | |
Speed | 1462.5 | rpm |
Electrical input | 20,443.95 | W |
Stator copper losses | 770.13 | W |
Stator core losses | 410.00 | W |
Rotor copper losses | 481.60 | W |
Stray load losses | 102.22 | W |
Friction losses | 180.00 | W |
Mechanical output | 18,500.00 | W |
Efficiency | 90.49 | % |
Nominal torque | 120.79 | Nm |
Stator resistance per phase | 0.56 | Ω |
Temperature coefficient | copper | |
Reference temperature | 20 | °C |
Operation temperature | 90 | °C |
Stator leakage reactance at 50 Hz | 1.52 | Ω |
Main field reactance at 50 Hz | 66.40 | Ω |
Rotor leakage reactance at 50 Hz | 2.31 | Ω |
Rotor resistance per phase | 0.42 | Ω |
Temperature coefficient | aluminium | |
Reference temperature | 20 | °C |
Operation temperature | 90 | °C |
See:
Anton Haumer, Christian Kral, Hansjörg Kapeller, Thomas Bäuml, Johannes V. Gragger
The AdvancedMachines Library: Loss Models for Electric Machines
Modelica 2009, 7th International Modelica Conference
Generated at 2024-11-23T19:25:52Z
by OpenModelicaOpenModelica 1.24.2 using GenerateDoc.mos