modelDCPM_Start

Test example: DC with permanent magnet starting with voltage ramp

Extends from Modelica.Icons.Example (Icon for runnable examples).

Information

Test example: Permanent magnet DC machine started with an armature voltage ramp
A voltage ramp is applied to the armature, causing the DC machine to start, and accelerating inertias.
At time tStep a load step is applied.
Simulate for 2 seconds and plot (versus time):
  • dcpm.ia: armature current
  • dcpm.wMechanical: motor's speed
  • dcpm.tauElectrical: motor's torque
Default machine parameters of model DC_PermanentMagnet are used.

Parameters

TypeNameDefaultDescription
SI.VoltageVa100Actual armature voltage
SI.TimetStart0.2Start of armature voltage ramp
SI.TimetRamp0.8Armature voltage ramp
SI.TorqueTLoad63.66Nominal load torque
SI.TimetStep1.5Time of load torque step
SI.InertiaJLoad0.15Load's moment of inertia
Utilities.ParameterRecords.DcPermanentMagnetDatadcpmDataDC machine data

Components

TypeNameDefaultDescription
Machines.BasicMachines.DCMachines.DC_PermanentMagnetdcpm
Modelica.Blocks.Sources.Rampramp
Modelica.Electrical.Analog.Sources.SignalVoltagesignalVoltage
Modelica.Electrical.Analog.Basic.Groundground
Modelica.Mechanics.Rotational.Components.InertialoadInertia
Modelica.Mechanics.Rotational.Sources.TorqueSteploadTorqueStep